ADR-3383: Device twins take odd bit depths only from a measured allow-list¶
- Status: Accepted
- Date: 2026-10-28
- Deciders: maintainer (milestone 0.1.0 order of 2026-10-27); RC4 WP13 (#2476)
- Tags: api, rc4, correctness, gpu
Context¶
ADR-2164 left refuse_unscaled_bpc() (core/src/feature/feature_extractor.cpp) as a deny-list: it refused 9, 11, 13, 14 and 15 bits for the device twins of the five picture_copy() families and let every other twin through. Twins outside that list were never compared with the CPU at those depths either. One of them is wrong: the CUDA, HIP and SYCL float_moment twins scale samples with a factor that is 1.0 at every depth but 10, 12 and 16 bits (moment_cuda_scaler(), moment_hip_scaler(), the SYCL host), so at 9, 11, 13, 14 and 15 bits they return the unscaled moments while the CPU (picture_copy(), ADR-2164) scales them. Issue #2476 asks that the library refuse depths other than 8, 10, 12 and 16 by name until the twin matrix passes.
Decision¶
refuse_unscaled_bpc()is an allow-list. A device twin (CUDA, SYCL, HIP, Metal) at a depth other than 8, 10, 12 or 16 bits returns-EINVALand logs<extractor>: picture bit depth N is not supported on this backend, unless it is listed as measured at that depth.- The list (
kMeasured) holds exact extractor names, each with the highest depth its parity test carries:float_psnr_cuda,float_psnr_sycl,float_psnr_hip,ciede_cuda,ciede_syclandciede_hipup to 15 bits (float_psnr_twin_odd_depths_exact(),ciede_twin_odd_depths(), ADR-2164);psnr_hvs_cuda,psnr_hvs_sycl,psnr_hvs_hipandinteger_psnr_hvs_metalup to 11 bits (hvs_twin_every_depth_identical()). No prefix match: an unlisted twin of a listed family, such asfloat_psnr_metal, is refused. - A twin joins the list by exact name in the pull request that adds the depths to its parity test, with every cell equal to the CPU (or within its declared
LIBM_TWINSbound). - CPU extractors are unaffected.
Alternatives considered¶
| Option | Pros | Cons | Why not chosen |
|---|---|---|---|
| Allow-list of exact twin names with a maximum depth (chosen) | Fails closed; a new twin is refused until measured; measured depths stay open | One line per twin to maintain | Chosen |
| Allow-list of family name prefixes | Shorter list | Lets the unmeasured float_psnr_metal and integer_ciede_metal through and refuses the measured psnr_hvs depths 9 and 11 | Rejected: the list must name what was measured |
Extend the deny-list with float_moment | Smallest change | Every future unmeasured twin is accepted silently again | Rejected: the defect class repeats |
Fix the float_moment scalers only | Removes the known wrong score | No device evidence for the other twins at odd depths | Not enough on its own; the scaler fix follows with its parity cells |
Consequences¶
- Positive: no device twin returns a score at an odd depth without parity evidence; the
float_momentwrong scores at odd depths are refused. - Negative: the
psnr_hvstwins are refused at 13, 14 and 15 bits and the Metalfloat_psnrandciedetwins at every odd depth until measured; the CPU extractors still score them. - Neutral / follow-ups: fix the
float_momenttwin scalers and add odd depths to the parity tests of each twin family; state rowT-FLOAT-EXTRACTORS-ODD-DEPTH-TWINS-UNMEASURED-2026-10-07.
References¶
- ADR-2164.
- Issue #2476 (RC4 WP13, input formats), acceptance: refuse other depths by name until the twin matrix passes (paraphrased).
- Tests:
core/test/test_read_pictures_bpc.c(test_unmeasured_twins_refuse_odd_depths,test_measured_twins_keep_odd_depths).